Calculation examples ηs

Calculation examples comparing the two methods from the old and new regulations are shown in the tables:

For LSH using gaseous or liquid fuel

Table: Seasonal space heating energy efficiency for products using gaseous or liquid fuel (due to changed calculation ηs for the old and new regulation is not directly comparable)

Product

Minimum ηs (%) 
Old regulation
(EU) 2015/1188

Minimum ηs (%) 
New regulation
(EU) 2024/1103

Comments
a. Open-fronted LSH 
using gaseous or liquid fuel (in (EU) 2024/1103 also open to chimney LSH)
42,040,3The 2024 regulation
includes open to 
chimney 
products.
b. Closed fronted open combustion LSH 
using gaseous or liquid fuel
72,063,6 
c. Balanced flue LSH72,063,6New category 
in 2024 Regulation, in the old regulation they beloned to b.

 

For “electric LSH”, the changes in the calculation method lead to higher values for ηs requirements in the new regulation (EU) 2024/1103 (please see table below).

Table: Seasonal space heating energy efficiency for products using electric energy (due to changed calculation ηs for the old and new regulation is not directly comparable)

ProductMinimum ηs (%) 
Old regulation
(EU) 2015/1188
Minimum ηs (%) 
New regulation
(EU) 2024/1103
Comments
d. Electric portable LSH36,044,7 
e. Electric fixed LSH 
with a nominal heat output above 250 W
38,047,5 
f. Electric fixed LSH 
with a nominal heat output equal 
or below 250 W
34,043,1 
g. Electric storage LSH38,547,3 
h. Electric underfloor LSH38,047,5 
Electric radiant LSH35,0-Category is absent 
in 2024 Regulation 
(due to limited or 
no practical use).
i. Electric visibly glowing radiant 
LSH with a 
nominal heat output above 1.2 kW
35,046,8 
j. Electric visibly glowing radiant 
LSH with a nominal 
heat output equal or below 1.2 kW
31,040,5 
k. Electric visibly glowing radiant 
portable LSH
31,0 resp. 35,039,5New category 
in 2024 Regulation
n. Towel rails with a nominal 
heat output above 250 W
38,046,0New category 
in 2024 Regulation
o. Towel rails with a nominal 
heat output above 60 W
34,042,1New category 
in 2024 Regulation; they belonged to electric fixed LSH

In case of commercial LSH, the calculation methodology is unchanged and the requirements on seasonal space heating energy efficiency of old and new regulation are directly comparable. This results in truly stricter requirements. Please see table below:

Table: Seasonal space heating energy efficiency for commercial LSH

Productηs (%) 
Old regulation
(EU) 2015/1188
ηs (%) 
New regulation
(EU) 2024/1103
l. Luminous LSH85,090,0
m. Tube LSH74,080,0